Shop

Shop

(Showing 161 – 200 products of 204 products)

Show:

Toxo IgG/IgM Rapid – 30 Test

Highlights:
  • Toxo IgG/IgM Rapid Test is a lateral flow chromatographic immunoassay
  • Serum/ Plasma assay
  • Invitro Diagnostic Test
1,600.00

Troponin I Rapid – 10 Test

Highlights:
  • Point of Care test, suitable for emergency care
  • Limit of Detection (LOD) to cTnI complex of 0.3/0.5 ng/ml (S,P & WB)
  • LOD is calibrated by NIST standard
  • Can be used with serum, plasma, and whole blood.
  • Utilizes polyclonal and monoclonal antibody pair to reduce interference
1,400.00

TRUEchemie Adenosine Deaminase (ADA) TEST KIT

Highlights:
  • Ready-to-use, stable liquid reagent of 2:1 ratio
  • Linearity up to 200 U/L
  • Hemoglobin (≤  800 mg/dL), Intralipid (≤  1000 mg/dL)
  • and ascorbic acid (≤  50 mg/dL) do not interfere
  • Packed with calibrator
1,950.00

TRUEchemie ALBUMIN Test Kit

Highlights:
  • Ready- to-use, Liquid stable mono reagent
  • BCG method with End Point Reaction
  • Detection range of 0.130 g/dL to 7.5 g/dL
  • Results in just 3 minutes
  • Reagents and standards specially stabilized
475.00

TRUEchemie Alpha Amylase

Highlights:
  • Ready-to-use, single reagent
  • Linearity up to 2000 U/L
  • Bilirubin (mixed isomers) < 10 % interference up to 600 µmol/L, haemolysis < 10 % interference up to 5 g/L and lipemia < 10 % interference up to 5 g/L
  • Factor or calibrator-based assay
1,300.00

TRUEchemie ALT (SGPT) TEST KIT

Highlights:
  • Ready to use liquid stable double reagent of 4:1 ratio.
  • Based on IFCC method.
  • Linearity up to 500 U/L, NADH and enzymes specially stabilized
  • Shelf life of 18 months at 2-8°C.
  • Pack size- Open reagents 1×50 mL / 2×50 mL & System pack 2x225T.

TRUEchemie ASO Test Kit is

Highlights:
  • Used for qualitative and semi quantitative determination of ASO in Serum
  • Rapid screening within 2 minutes
  • Highly stabilized latex reagent
  • Distinct agglutination with sensitivity of 200 IU/mL
  • Packed with positive and negative controls

TRUEchemie ASO Turbilatex

Highlights:
  • Ready-to-use, stable liquid reagent of 4:1 ratio
  • Detection range of 20 to 800 U/mL
  • No prozone effect up to 3000 U/mL
  • Bilirubin (≤ 20 mg/dL), hemoglobin (≤ 10 g/L), lipemia (≤10 g/L) and rheumatoid factors (≤ 600 U/mL) do not interfere
  • Reaction time just 2 minutes
  • Packed with calibrator
2,350.00

TRUEchemie AST (SGOT) TEST KIT

Highlights:
  • Ready to use liquid stable double reagent of 4:1 ratio.
  • Based on IFCC method.
  • Linearity up to 500 U/L, NADH and enzymes specially stabilized
  • Shelf life of 18 months at 2-8°C.
  • Pack size- Open reagents 1×50 mL / 2×50 mL & System pack 2x225T.
1,150.00

TRUEchemie Bilirubin – Total Test Kit

Highlights:
  • Reliable
  • Accurate
  • Cost effective
850.00

TRUEchemie Calcium Test Kit

Highlights:
  • Ready- to-use, Liquid stable mono reagent
  • Arsenazo III method with End point reaction
  • Detection range of 0.85 mg/dL to 25 mg/dL
  • Results in just 3 minutes
  • Results comparable with O-CPC method
  • Packed in monovials to avoid reagent contamination
950.00

TRUEchemie Chloride Test Kit

Highlights:
  • Ready- to-use, Liquid stable mono reagent
  • Thiocyanate method with End point reaction
  • Detection range of 2.10 mmol/L to 150 mmol/L
  • Results in just 5 minutes
  • Hemoglobin 1000 mg/ dL , Bilirubin up to 20 mg/dl and Lipemia 1000mg/dl does not interfere
  • Packed in monovials to avoid reagent contamination
  • Results comparable to ISE and Titrimetric methods
650.00

TRUEchemie CK NAC

Highlights:
  • Ready-to-use, stable liquid reagent of 4:1 ratio
  • Detection range of 5 to 1200 U/L
  • Glucose (≤ 7 g/L), bilirubin(≤  600 µmol/L), hemoglobin(≤  1.25 g/L) and triglycerides (≤
    2.5 g/L) do not interfere
  • Factor or calibrator-based assay
2,300.00

TRUEchemie CK-MB

Highlights:
  • Ready-to-use, stable liquid reagent of 4:1 ratio
  • Detection range of 1.9 to 1000 U/L
  • Glucose (≤ 7 g/L), bilirubin (≤ 600 µmol/L), hemoglobin(≤ 1.25 g/L) and triglycerides (≤ 2.5 g/L) do not interfere
  • Factor or calibrator-based assay
4,250.00

TRUEchemie CRP Test kit

Highlights:
  • Ready-to-use, stable liquid reagent of 4:1 ratio
  • Detection range of 2 to 150 mg/L
  • No prozone effect up to 1000 mg/L
  • Bilirubin (≤ 20 mg/dL), lipemia (≤ 10 g/L) and rheumatoid factors (≤ 300 U/mL) do not interfere
  • Reaction time just 2 minutes
  • Packed with calibrator
2,400.00

TRUEchemie D-Dimer

Highlights:
  • Immunoturbidimetric method, liquid stable reagents & linearity up to 10 µg FEU/mL
  • Ready to use liquid calibrator with excellent stability
  • Results in 7 minutes
  • No interference of Bilirubin ≤ 60 mg/dL, Triglycerides ≤700 mg/ dL and Haemoglobin ≤ 350 mg/ dL.
  • Shelf life of 15 months when stored at 2-8°C
10,700.00

TRUEchemie DIRECT HDL CHOLESTEROL KIT

Highlights:
  • Reliable
  • Accurate
  • Cost effective
2,850.00

TRUEchemie DIRECT LDL CHOLESTEROL KIT

Highlights:
  • Reliable
  • Accurate
  • Cost effective
4,000.00

TRUEchemie EZ CLEANER -1 x 50 ml

Highlights:
  • High Quality Reagents
  • Cyanide-free lyse
  • Reagents shelf life up to 24 months
  • Environmental friendly diluent and cleaner reagents (Azide Free)
1,000.00

TRUEchemie Glucose Test Kit

Highlights:
  • Ready-to -use.
  • Liquid stable mono-reagent.
  • GOD-POD method.
  • Wide detection range of 0.800 mg/dL to 600 mg/dL.
  • Excellent shelf life.
1,450.00

TRUEchemie HbA1c Test Kit

Highlights:
  • Ready-to-use, stable liquid reagent of 3:1 ratio
  • Wide measuring ranges from 2-16 %
  • Stable for 30 days on board (2-8 ºC)
  • Excellent correlation with HPLC
  • No cross reaction with other variants
  • Packed with 5 calibrators

TRUEchemie Inorganic Phosphorus Test kit

Highlights:
  • Ready- to-use, Liquid stable mono reagent
  • Ammonium molybdate method with End point Reaction
  • Detection range of 0.56 mg/dL to 20 mg/dL
  • Results in just 5 minutes
  • Packed in monovials to avoid reagent contamination
780.00

TRUEchemie LIPASE TEST KIT

Highlights:
  • Ready- to-use, Liquid stable reagents of 4:1 ratio
  • Enzymatic Colorimetric method
  • Linearity up to 250 U/L
  • Ascorbic Acid up to 30 mg/dL Bilirubin up to 60 mg/dL, Hemoglobin 1000 mg/dL do not interfere
  • Fixed time reaction with reaction time just 2 minutes
3,950.00

TRUEchemie LYSE REAGENT -1 x 500 ml

Highlights:
  • High Quality Reagents
  • Cyanide-free lyse
  • Reagents shelf life up to 24 months
  • Environmental friendly diluent and cleaner reagents (Azide Free)
3,200.00

TRUEchemie Micro Albumin Test Kit

Highlights:
  • Ready-to-use, stable liquid reagent of 4 :1 ratio
  • Detection range of 2 to 150 mg/L
  • No prozone effect up to 1000 mg/L
  • Glucose (≤ 2 g/L), hemoglobin (≤ 10 g/L) and creatinine (≤3 g/L) do not interfere
  • Reaction time just 2 minutes
  • Packed with calibrator
3,850.00

TRUEchemie POTASSIUM TEST KIT

Highlights:
  • Ready to use liquid stable mono-reagent.
  • Based on Colorimetric method. 
  • Linearity up to 8.5 mmol/L and results comparable with ISE.
  • Packed in monovials to avoid reagent contamination.
  • Shelf life of 2 years at 2-8°C.
  • Pack size- Open reagent 50 Test & System pack 4x 65T
1,100.00

TRUEchemie PROBE CLEANER -1 x 50 ml

Highlights:
  • High Quality Reagents
  • Cyanide-free lyse
  • Reagents shelf life up to 24 months
  • Environmental friendly diluent and cleaner reagents (Azide Free)
1,000.00

TRUEchemie RF / RA (Rheumatoid Factor / Rheumatoid Arthritis) test Kit

Highlights:
  • Used for qualitative and semi quantitative determination of RF in Serum
  • Rapid screening within 2 minutes
  • Highly stabilized latex reagent
  • Distinct agglutination with sensitivity of 12 IU/mL
  • Packed with positive and negative controls
  • Necessary accessories provided
1,050.00

TRUEchemie RF-Turbilatex

Highlights:
  • Ready-to-use, stable liquid reagent of 4:1 ratio
  • Detection range of 6 to 160 U/mL
  • No prozone effect up to 800 U/mL
  • Hemoglobin (≤  10 g/L), bilirubin (≤  20 mg/dL) and
  • lipemia (≤  10 g/L) do not interfere
  • Reaction time just 2 minutes
  • Packed with calibrator
2,600.00

TRUEchemie Sodium Test Kit

Highlights:
  • Ready- to-use, Liquid stable mono reagent
  • Colorimetric method with End point reaction
  • Detection range of 2.30 mmol/L to 180 mmol/L
  • Results in just 5 minutes
  • Results comparable to ISE and flame photometry methods
  • Packed in monovials to avoid reagent contamination
1,150.00

TRUEchemie Uric Acid

Highlights:
  • Ready- to-use, Liquid stable mono reagent
  • Uricase -POD method with end point reaction
  • Detection range of 0.03 mg/dL to 25 mg/dL
  • BLANIL -6 stabilizers and Liposol incorporated
  • Can be used in Calorimeters, semi and fully automated instruments
1,150.00

Trustcheck BPM 2.0 Digital Blood Pressure Monitor

Highlights:
Product Type  Upper arm type-B56
Measurement Range DIA: 40-130mmHg; SYS: 60-230mmHg
Pulse 40-199beats/min
Blood pressure +3mmHg
Accuracy Blood pressure: +3mmHg
Pulse: ±5% of the reading
Memory 2*120 groups memory (Double users)
Material ABS+LCD display
Cuff Circumference 22-40cm
Power Source Internal-DC 6V (4 AAA)/External-DC 5V 1A

TSH ELISA

Highlights:
  • Sensitivity: Detects TSH levels as low as 0.035 µIU/mL
  • Specificity: No cross reactivity detected with related hormones: FSH, LH and hCG
  • Linearity: 1:128 dilution on 36 ?IIU/mL sample
  • Precision: intra assay precision: CV 7.5%; inter assay precision: CV 8.0 %
  • Accuracy: R2= 0.986 against Roche TSH Chemiluminescence Immunoassay
  • Hook effect: No hook effect up to 8000 μIU/mL
  • Interference: not affected by Hemoglobin 500mg/dL, Diltiazem 15uM, Bilirubin 20 mg/dL, Erythromycin 81.6uM, Triglycerides 3g/dL, Verapamil 4.4uM, HAMA 52.5ng/mL, T3 100ng/mL, RF 215IU/mL, T4 100ug/dL, Acetaminophen 1324uM
  • Calibration: Human TSH WHO 3rd International Standards (81/565 NIBSC)
  • Calibrators: 0, 0.5, 2.0, 5.0, 10, 20, 40 µIU/mL in biological matrix
  • Shelf life: 18 months
  • Assay time: 80 minutes
2,850.00
Post your Requirement
Close
Close
Close

My Cart