ELISA

ELISA

Showing all 23 results

Show:

AMH ELISA

Highlights:
  • Accuracy: R2 = 0.96 (with Siemens CLIA)
  • Analytical Sensitivity: 0.023ng/mL
  • Specificity: No-cross reactivity with other fertility hormones
  • Linearity: 0 – 14ng/mL
  • Intra & Inter assay precision: CV <=10%
11,100.00

Chikungunya IgM ELISA

Highlights:
  • A solid phase enzyme linked immunoabsorbent assay for the qualitative detection of IgM anti- Chikungunya virus in human serum or plasma.
14,000.00

Dengue IgG ELISA

Highlights:
  • Sensitivity:96.4%
  • Specificity:98.1%
  • SeraCare AccuSet Performance Panel (0845-0051): 100% agreement with a market leading Dengue IgG Capture ELISA
  • Cross Reactivity: No cross reaction with HCV, Syphilis, HBsAg, ANA, HIV, HAMA, H. pylori, RF, Malaria
  • Interference: No interference with Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 1.3 %;Heparin: 3,000 U/L; Creatinine: 5 mmol/L; Bilirubin: 10 mg/dL; EDTA: 3.4 ?mol/L
  • Intra Assay Precision: CV < 7%
  • Inter Assay Precision: CV < 6%
  • Shelf life: 18 months
8,800.00

Dengue IgM ELISA

Highlights:
  • Sensitivity:  96.6%
  • Specificity: 98.1%
  • SeraCare AccuSet Performance Panel (0845-0051): 100% agreement with a market leading Dengue IgM Capture ELISA
  • Cross Reactivity: No cross reaction with CHIK, HCV, Syphilis, HBsAg, ANA, HIV, HAMA, H. pylori, RF, Malaria
  • Interference: No interference with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 1.3 %;Heparin: 3,000 U/L;  Creatinine:  442µmol/L; Bilirubin:  10 mg/dL; EDTA: 3.4 µmol/L
  • Intra Assay Precision: CV: <7%
  • Inter Assay Precision: CV: <10%
8,900.00

Dengue NS1 ELISA

Highlights:
  • Analytic sensitivity: Detects recombinant Dengue type 2 NS1 at a level as low as 0.3 ng/mL.
  • Sensitivity: 100%
  • Specificity: 97.8%
  • SeraCare Dengue Early Infection AccuSet Performance Panel: 100% agreement with PanBio Dengue Early ELISA
  • Cross Reactivity: No cross reaction with HCV, Syphilis, HBsAg, ANA, HIV, HAMA, H. pylori, RF, Malaria
  • Hook Effect: No hook effect up to 0.1 mg/mL
  • Interference: No interference with Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 1.3 %;Heparin: 3,000 U/L; Creatinine: 5 mmol/L; Bilirubin: 10 mg/dL; EDTA: 3.4 ?mol/L
  • Intra Assay Precision: CV < 10%
  • Inter Assay Precision: CV < 7%
  • Shelf life: 18 months
9,300.00

Free T3 ELISA

Highlights:
  • A competitive solid-phase enzyme-linked immunoabsorbant assay for the quantitative determination of free triiodothyronine (fT3) levels in human serum.
  • Sensitivity: 274 ± 0.077 pg/mL at 95% confidence level
  • Specificity: <0.001 cross reactivity with l-thyroxine at 10 µg/mL, iodotyrosine at 10 µg/mL, diiodotyrosine at 10 µg/mL, and d-thyroxine at 10 µg/mL, respectively
  • Accuracy: correlation coefficient 0.958 ± 0.087 at 95% confidence level
  • Intra Assay Precision: CV < 5.1%
  • Inter Assay Precision: CV < 7.5%
  • Shelf life: 18 months
3,500.00

Free T4 ELISA

Highlights:
  • Analytical Sensitivity: 0.202 ng/dL.
  • Linearity: 0 – 8 ng/dL.
  • Method of Comparison: r= 0.964 with reference ELISA.
  • Intra-assay precision: CV < 4.66 %.
  • Inter-assay precision: CV < 8.7 %.
3,550.00

HAV IgM ELISA

Highlights:
  • Utilizes IgM capture technique
  • Detects IgM anti-HAV in serum or plasma
  • Evaluated with BBI HAV serum conversion and HAV mixed titer performance panels
  • Useful for identifying acute HAV infections
6,400.00

HBsAg ELISA Kit

Highlights:
  • Based on double Ab-Sandwich immunoassay technique ensure high specificity
  • Solid microwells pre-coated with monoclonal anti-HBsAg antibodies
  • Liquid conjugates composed of polyclonal anti-HBsAg Ab conjugated with HRP
  • Relative sensitivity: 100% and specificity: 99.78 %
  • Comparable accuracy to the leading other ELISA kits
  • Clear borderlines with high accuracy positive and negative controls
  • Breakaway microwell strips
  • Evaluated by NIB
1,350.00

HCV IgG ELISA Kit

Highlights:
  • Based on indirect immunoassay technique ensure high specificity
  • Solid microwells pre-coated with recombinant HCV antigens
  • Liquid conjugates composed of anti-human IgG conjugated with HRP
  • Relative Sensitivity: 100 %, Specificity: 99.81 %
  • Comparable accuracy to the leading other ELISA kits
  • Clear borderlines with high accuracy positive and negative controls
  • Breakaway microwell strips
  • Evaluated by NIB
  • Assay time: 90 Minutes
2,100.00

HEV IgM ELISA

Highlights:
  • Utilizes IgM capture technique.
  • Suitable for diagnosing acute HEV infection.
  • Assay time: 75 Mins.
  • Sensitivity: 100% & Specificity: 100%.
  • Utilizes IgM capture technique.
  • Suitable for diagnosing acute HEV infection.
  • Assay time: 75 Mins.
  • Sensitivity: 100% & Specificity: 100%.
6,450.00

HIV 1+2 Ab ELISA Kit

Highlights:
  • Based on double Ag-Sandwich immunoassay technique to ensure high specificity
  • Solid microwells pre-coated with recombinant HIV-1 and HIV-2 Ag
  • Liquid conjugates composed of recombinant HIV-1 and HIV-2 Ag conjugated with HRP
  • Relative sensitivity: 100% and specificity: 99.9 %
  • Comparable accuracy to the leading other ELISA kits
  • Clear borderlines with high accuracy positive and negative controls
  • Breakaway microwell strips
  • Evaluated by NIB
  • Assay time: 90 Minutes
1,900.00

HIV Ag-Ab ELISA Kit

Highlights:
  • Based on double Ag/Ab-Sandwich immunoassay technique to ensure high specificity
  • Solid microwells pre-coated with recombinant HIV-1, HIV-2 Ag and Anti-P24 Ab
  • Liquid conjugates composed of recombinant HIV-1, HIV-2 Ag & SA conjugated with HRP
  • Relative sensitivity: 100% and specificity: 99.9 %
  • Comparable accuracy to the leading other ELISA kits
  • Clear borderlines with high accuracy positive and negative controls
  • Breakaway microwell strips
  • Evaluated by NIB
  • Assay time: 90 Minutes
2,700.00

Leptospira ELISA

Highlights:
  • Sensitivity: 86.7%
  • Specificity: 96.8%
  • Cross Reactivity: No false positive results were observed on specimens from Dengue, Malaria, Typhi, ANA, HAMA, RF, HIV, HBsAg, HCV, Syphilis, pylori
  • Interference: No interference was seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 1.3 %;Heparin: 3,000 U/L; Creatinine: 5 mmol/L; Bilirubin: 10 mg/dL; EDTA: 3.4 µmol/L
  • Shelf life: 12 months
11,700.00

Malaria ELISA

Highlights:
  • Target: Pf HRP II and pLDH based detection
  • LOD: pLDH – 10 parasites/uL against WHO Standard
    pfHPRP-II – 20 parasites/uL against FIND Standard
  • Specificity: No cross-reactivity with dengue, chikungunya & filarial infection
  • Precision: CV-10%
  • Better sensitivity at 95% CI than competitors
  • LOD is calibrated against WHO and FIND Standard
2,000.00

STANDARD E Dengue IgG Elisa

Highlights:
  • Simple and easy to use – All necessary reagents included in the kit
  • Highest accuracy with all dengue serotypes(DEN1,2,3, and 4)
  • Able to detect antibodies in samples with high sensitivity and specificity
  • Sensitivity:-97.2%;Specificity:-96.2%
9,500.00

STANDARD E Dengue IgM Elisa

Highlights:
  • Simple and easy to use – All necessary reagents included in the kit
  • Highest accuracy with all dengue serotypes(DEN1,2,3, and 4)
  • Sensitivity:-98.2%;Specificity:-95.4%
9,500.00

STANDARD E Dengue NS1 Elisa

Highlights:
  • Simple and easy to use: All necessary reagents included in the kit
  • Highest accuracy with all dengue serotypes(DEN1,2,3, and 4)
  • Able to detect antigens in samples with high sensitivity and specificity
  • Sensitivity:-93.5%;Specificity:-94.3%
9,400.00

Syphilis Ab ELISA Kit

Highlights:
  • Qualitative detection of antibodies (IgG, IgM, IgA) against Treponema pallidum (Tp).
  • Based on double Ag-sandwich immunoassay technique to ensure high specificity
  • Solid microwells pre-coated with recombinant Tp antigens
  • Liquid conjugates composed of recombinant Tp antigens conjugated with HRP
  • Sensitivity: 100%, Specificity: 99.8%, Shelf life: 12 months at 2-8°C
  • Assay time: 70 minutes
2,250.00

Total T3 ELISA

Highlights:
  • A solid phase enzyme linked immunoabsorbant assay for the quantitative determination of total Triiodothyronine (T3) levels in human serum.
3,200.00

Total T4 ELISA

Highlights:
  • A solid phase enzyme linked immunoabsorbant assay for the quantitative measurement of total Thyroxine (T4) in human serum
3,000.00

TSH ELISA

Highlights:
  • Sensitivity: Detects TSH levels as low as 0.035 µIU/mL
  • Specificity: No cross reactivity detected with related hormones: FSH, LH and hCG
  • Linearity: 1:128 dilution on 36 ?IIU/mL sample
  • Precision: intra assay precision: CV 7.5%; inter assay precision: CV 8.0 %
  • Accuracy: R2= 0.986 against Roche TSH Chemiluminescence Immunoassay
  • Hook effect: No hook effect up to 8000 μIU/mL
  • Interference: not affected by Hemoglobin 500mg/dL, Diltiazem 15uM, Bilirubin 20 mg/dL, Erythromycin 81.6uM, Triglycerides 3g/dL, Verapamil 4.4uM, HAMA 52.5ng/mL, T3 100ng/mL, RF 215IU/mL, T4 100ug/dL, Acetaminophen 1324uM
  • Calibration: Human TSH WHO 3rd International Standards (81/565 NIBSC)
  • Calibrators: 0, 0.5, 2.0, 5.0, 10, 20, 40 µIU/mL in biological matrix
  • Shelf life: 18 months
  • Assay time: 80 minutes
2,850.00

Vitamin D ELISA

Highlights:
  • Accuracy: R2 = 0.918 with CLIA as reference.
  • Analytical Sensitivity: 1.2 ng/mL.
  • Specificity: No cross reactivity to non-hydroxylated vitamin D2 and Vitamin D3.
  • Intra & Inter assay precision: CV <=10%.
  • Higher linearity: 0-150 ng/mL.
  • 1 step less procedure, faster resulting.
  • High & Low level assay controls included.
  • Accuracy: R2 = 0.918 with CLIA as reference.
  • Analytical Sensitivity: 1.2 ng/mL.
  • Specificity: No cross reactivity to non-hydroxylated vitamin D2 and Vitamin D3.
12,000.00
Post your Requirement
Close
Close
Close

My Cart

Shopping cart is empty!

Continue Shopping